The 525 is used for heated applications up to 400°F (205°C)
which require large reservoirs made form stainless steel, or a heated
valve that can be located remote from the reservoir. The system consists
of four separate, but integrated, elements:
- Heated
reservoir of 1, 2 (2 gallon is standard), 5, 10 gallon or larger
capacity;
- Heated
feed line;
- Heated
valve with integral flow control;
-
Valve controller.
Each of the three heated components has its own temperature control.
|
Operation
UNACTUATED - When the user-supplied 3-way normally closed valve is off,
the pinching surface of the spring loaded piston prevents flow by collapsing
the tube. The patented pinch stop adjusting screw limits tube stress and
provides a fixed start position for the piston. This control greatly extends
the tube life and insures shot to shot repeatability.
ACTUATED
- When the user-supplied 3-way valve is on, air moves the pinch piston
back to the adjustable micrometer stop. This controls the amount the tube
opens, which, in turn, controls the flow rate of the fluid. This action,
combined with the nozzle size (if a nozzle is used) and the time the 455
valve is open, governs the amount of fluid that is dispensed.
The operator
sets the temperature controls to obtain optimum viscosity characteristics,
and then sets the dispense controller to adjust the application volume.
When the
operator closes the cycle start switch, the patented valve, which has
its own flow adjustment, opens a controlled amount for a precise, adjustable
time. This action allows an exact, repeatable amount of fluid to be dispensed
from the constantly pressurized reservoir.
The manual
mode operation allows material to be dispensed for intervals at the operators
discretion. The operator has separate temperature controls for the 3 elements.
Standard reservoir is 2 gallons (7.6 liters). |
System
Includes:
One Model 525 valve
One Model 525 valve controller
One 2 gallon heated reservoir with controls (consult factory for
other sizes)
One 5 foot heated feed line
One dual temperature control for line and valve
Air lines and fittings
External filter regulator
Foot Switch
Nozzle - .070 I.D. standard (consult factory for other sizes)
Specifications
Power Required: 115 volts, 1 amp
Air Required: 60 psi
Dimensions: Valve approx. 1" diameter x 4.034" long
Controller (temp) L 10", W 8", H 4"
Controller (valve) L 10", W 8", H 4"
Reservoir w/ Control 12" diameter x 18.034; H
Feed line 1" diameter x 15 ft long
Weight: 12 lbs |
|
|
|